The EasyGas™ 1000 gas cabinet is designed to cover a wide range of cylinder gas delivery applications.
In its simplest form, the EasyGas™ gas cabinet houses 1, 2, 3 or 4 gases, and includes a high purity, manual gas panel for each gas. Modular EasyGas™ panels are available in 1, 2, 3, 4, 5 and 6-valve designs for process and instrumentation diagrams. Each panel may be tailored to the specific gas and application.
With the addition of the optional FlexPowr™ controller, the EasyGas™ cabinet can support a myriad of automated alarm and panel shutdown options such as: auto-switchover, excess flow sensors, low cylinder pressure alarms, high delivery pressure alarms, gas leak sensors, Scales and more. The FlexPowr™ controller can support up to eight (8) user-settable alarm inputs and eight (8) user-settable alarm outputs.
EasyGas™ 1000 makes it simple to meet your exact gas delivery needs. Our modular design concept allows you to use a building-block method to configure a gas cabinet to your specifications.
STANDARD CONFIGURATION
- 1-cyl, [1-process].
- 2-cyl, [1-process, 1-purge].
- 2-cyl, [2-process]*.
- 3-cyl, [3-process]*.
- 3-cyl, [2-process, 1-purge].
- * Purge SideCar is an external, integrated purge cylinder.
Cylinder Cabinets:
- UHP construction: orbitally welded/VCR® 316L SS or VIM/VAR.
- UHP grade regulator (nontied diaphragm standard).
- UHP grade diaphragm valves (20 Ra standard).
Gas Panel / Manifold Purity:
- 3-Valve design [HP vent].
- 4-Valve design [adds PURGE].
- 6-Valve design [adds EVAC].
HP Gas Panels:
- 25 Ra surface finish.
- Dual stage regulators.
- Outlet filters (0.003 µm).
- DISS cylinder fittings.
- 3-Valve process gas panel [adds HP vent, 1-Valve is standard].
UHP Gas Panels:
- Automatic shutdown of process gas panels.
- Up to 8 user-definable alarms.
- Up to 8 user-definable outputs.
- Audible/visible alarm indication.
- EMO button.
- Multilevel password protection.
- CLASS 100/CLASS 10 clean room assembly and test.
Optional FlexPowr™ Controller:
- Exhaust pressure switch.
- HI cylinder pressure switch.
- HI delivery pressure switch.
- Integrated gas leak detection.
- UVIR detection.
- Excess flow sensor.
FlexPowr™ Control Components:
- Adjustable cylinder shelves.
- Restrictive flow orifices.
- Cylinder scales.
- CGA torque wrenches.
Other Equipment Options:
- 1-cil: 18 “W x 72” H x 19 “D .
- 2-cil: 24″ W x 72″ H x 19″ D .
- 3-cil: 36″ W x 72″ H x 19″ D .
Dimensions:
- ASME Section IX.
- SEMI® S2 Safety Guidelines for Semiconductor Manufacturing Equipment.
- NFPA® 79, 496, 70 [NEC®].
- Factory Mutual®.
- UL®.
- CE®.
Codes & standards:
FACILITIES REQUIREMENTS
- Process Purge : Adjustable to 85 psig 30 slm máx.
- Vacuum Drive : Adjustable to 85 psig 85 slm máx.
- Process Vent : > 1.0″WC 100 slm.
- Pneumatic Supply: Adjustable to 90 psig 1 slm máx.
- Electrical : 115V/3A N/A.
- Sprinkler (if used): 30 psig 31 gpm.
- Exhaust : > 0,15″ WC 300 scfm (2-cil), 450 scfm (3-cil).
*Note: Electrical varies with country; facilities requirements vary with system options. Consult Factory for details.