The EasyExhaust™ 410 will first thermally decompose/oxidize gases in a furnace, then pass the gases through a water spray packed tower to wet scrub, remove particles and cool the exhaust gases prior to exiting the system.
The gas abatement systems provide proper safety to plant and personnel in the handling of hazardous gases.
An optional pH monitoring system can neutralize acidic scrubbing liquid. We have taken extensive measures to provide fail-safe designs and combine them with forward thinking features in an effort to offer a safe, versatile product for specialty gas exhaust requirements.
FEATURES
- Furnace operating temperature up to 900 °C.
- Digital temperature setpoint and readout.
- Vertically mounted, inconel reaction tube with water cooled top flange.
- Air flowmeter for oxidation.
- Dry type air pump.
- Water spray packed tower exhaust.
- Pressure monitor interlocks out system and sounds an audible alarm if system clogs.
- Automatic PLC system control.
FACILITIES REQUIREMENTS
- Dimensions : 29″ Length , 29″ Width , 75″ Height.
- Electrical* : 208 VAC , 60 Hz , L1, L2, L3, N, G , 40 Amps.
- Condition Gas Exhaust : 50 SCFM , 1″ WC.
- Cabinet Exhaust : 200 SCFM , 1″ WC.
- Water : 1 GPM , 20 – 50 PSIG.
- Water Drain : Gravity drain.
- *NOTE : Electrical varies with country, Facilities requirements vary with system options, Consult Factory for details.